Ask Question
12 January, 14:31

The two pond system is fed by a stream with flow rate 1.0 MGD (million gallons per day) and BOD (nonconservative pollutant) concentration of 20 mg/L. The rate of decay of BOD is 0.3/day. The volume of the first pond is 5 million gallons and the second is 3 million. Assuming complete mixing within the pond, find the BOD concentration leaving each pond.

+5
Answers (1)
  1. 12 January, 15:00
    0
    Answer: First pond = 8.0 mg/L

    second pond = 4.2 mg/L

    Explanation:

    Cn/Co = [ 1 / [ 1 + (k*t/n) ]]

    for the first pond

    where Co into the first pond is 20mg/L,

    Cn = 20*[ 1 / [ 1 + ((1 x 5) / 0.3) ]]

    Cn = 8 mg/L

    into the second pond we calculate the BOD leaving the pond of volume 3million liters

    we have Cn = 4.2 mg/L
Know the Answer?
Not Sure About the Answer?
Find an answer to your question 👍 “The two pond system is fed by a stream with flow rate 1.0 MGD (million gallons per day) and BOD (nonconservative pollutant) concentration ...” in 📗 Engineering if the answers seem to be not correct or there’s no answer. Try a smart search to find answers to similar questions.