A solid square rod is cantilevered at one end. The rod is 0.6 m long and supports a completely reversing transverse load at the other end of + / - 2 kN. The material is AISI 1080 hot-rolled steel. If the rod must support this load for 104 cycles with a factor of safety of 1.5, what dimension should the square cross section have? Neglect any stress concentrations at the support end. Hint: Initially, assume the size endurance limit modification factor is kb=0.85; then check this assumption after the actual size is determined.

+1
Answers (1)
  1. 22 February, 06:40
    0
    Answer / Explanation:

    Given the data:

    Length of the rod (L) = 0.6m

    Load; F = ± 2 KN

    Ultimate strength; S u t = 770 M P a = 770 / 6.89 kpsi = 112 kpsi

    Yield strength; S y = 420 M P a

    Design factor = 1.5

    Surface factor; k a = 0.488

    Size factor; k b = 0.85

    Now by using mechanical engineering design data book,

    We calculate for fatigue strength

    So, Se¹ = 0.5 * 770

    Se¹ = 385 M P a

    K a = 57.7 * 770⁻⁰⁷¹⁸

    Kₐ = 0.488

    Assume Kb = 0.85 (check later)

    Se = Kₐ Kb Se¹

    Se = 0.488 * 0.85 * 385

    S e = 160 M P a

    By using design data book,

    a = (f Sut) ² / Se

    b = - 1 / 3 log f Sut / Se

    S f = ₐ N ᵇ

    Sf = 2553 (10⁴) ⁻ ⁰.²⁰⁰⁵

    S f = 403 M P a

    The expression for stress,

    M max = 2000 * 0.6

    M max = 1200 Newton per meter

    = M (b/2) / I = M (b/2) / bb³/12

    = 6M / b³ = 6 x 1200 / b³

    = 7200 / b³ Pa

    Now by comparing strength and stress,

    S f = n * σ a

    = 403 * 10 ⁶

    = 1.5 * 7200 / b³

    where b = 0.0299 m

    b = 30 m m

    So, we assume the size factor, so the expression for checking the size factor is,

    By using design data book,

    de = 0.808 (hb) ∧ 1/2

    de = 0.808 b

    de = 0.808 * 30

    de = 24.2

    Kb = (24.2 / 7.62) ∧-0.107

    Kb = 0.88

    We have assume 0.85 which is nearer to the 0.88 and it is acceptable.

    So the dimension of the square is 30 mm
Know the Answer?
Not Sure About the Answer?
Find an answer to your question 👍 “A solid square rod is cantilevered at one end. The rod is 0.6 m long and supports a completely reversing transverse load at the other end ...” in 📗 Engineering if the answers seem to be not correct or there’s no answer. Try a smart search to find answers to similar questions.