Ask Question
27 July, 10:09

A 1000 W iron utilizes a resistance wire which is 20 inches long and has a diameter of 0.08 inches. Determine the rate of heat generation in the wire per unit volume, in Btu/hrft3, and the heat flux on the outer surface of the wire, in Btu/hrft2, as a result of this generation.

+5
Answers (1)
  1. 27 July, 10:22
    0
    The rate of heat generation in the wire per unit volume is 5.79*10^7 Btu/hrft^3

    Heat flux is 9.67*10^7 Btu/hrft^2

    Explanation:

    Rate of heat generation = 1000 W = 1000/0.29307 = 3412.15 Btu/hr

    Area (A) = πD^2/4

    Diameter (D) = 0.08 inches = 0.08 in * 3.2808 ft/39.37 in = 0.0067 ft

    A = 3.142*0.0067^2/4 = 3.53*10^-5 ft^2

    Volume (V) = A * Length

    L = 20 inches = 20 in * 3.2808 ft/39.37 in = 1.67 ft

    V = 3.53*10^-5 * 1.67 = 5.8951*10^-5 ft^3

    Rate of heat generation in the wire per unit volume = 3412.15 Btu/hr : 5.8951*10^-5 ft^3 = 5.79*10^7 Btu/hrft^3

    Heat flux = 3412.15 Btu/hr : 3.53*10^-5 ft^2 = 9.67*10^7 Btu/hrft^2
Know the Answer?
Not Sure About the Answer?
Find an answer to your question 👍 “A 1000 W iron utilizes a resistance wire which is 20 inches long and has a diameter of 0.08 inches. Determine the rate of heat generation ...” in 📗 Engineering if the answers seem to be not correct or there’s no answer. Try a smart search to find answers to similar questions.